LANpoint 7 & LANpoint CE.NET Vehicle Mount Power Supply Specifications Page


Vehicle Mount Power Supply Specifications

Aluminum enclosure. LPP105 is also epoxy-filled.

Constructed to a high standard to tolerate adverse environmental conditions.

Durable for vehicular applications.

Supports battery supply variations.

High and low voltage windows for shutoff, to protect the terminal from overvoltage damage.

Remote low power switch on all units. Can also be wired for direct connection.

Vehicle Mount Power Supplies - Common Specifications and Characteristics

Efficiency: >80%.

Switching Frequency: 50 KHz.

All units are CE Marked.

Conformance to: EMC EN 55022, EN50081-1, EN50082-1, FCC Class B, UL 1950.

Input Protection: Reverse polarity, with additional protection: (See below)

Output Protection: (See below)

Mounting: All mounting holes 5 mm (.2") diameter.

Weight: LPP101(12VDC) & LPP102(24VDC): .5 Kg / 1.1 lbs.; LPP103(36VDC) & LPP104(48VDC): .35 Kg / .8 lbs; LPP105(72VDC): 1.6Kg / 3.5 lbs.

Remote Switch: All units

Switch connection: To use remote switch, connect the remote input to one side of switch, and the + input to the other side. If switch is not required, the switch input must be connected to + input.

Nominal input voltage must be applied to remote switch line to turn unit on.


Part Number

DC Input
Voltage
Nominal

Range

Output Voltage (Nominal)

Output
Current
Continuous

Max

Output
Voltage
Regulation
0-10%**

0-100%**

Output Ripple (mV)

No-Load Input (mA)

Protection
Input/
Output

LPP101

12.0

11–15

24.0 ±.5

2.5A***

3A / 30

0.4V

0.2V

<60

<100

A / D

LPP102

24.0

18–32

24.0 ±.5

3A***

5A / 15

0.4V

0.2V

<50

<100

C / E

LPP103

36.0

 

24.0 ±.5

 

 

 

 

 

 

/D

LPP104

48.0

29–59

24.0 ±.5

2.5A****

3A / 30

0.2V

0.1V

<100

<20

B / E

LPP105

72.0

70–140

24.0 ±.5

5A

 

0.4V

0.6V

<100

<40

E / F


* 50% duty cycle, 30 minutes
** Percentage of load
*** Current at 40º C
**** Current at 30º C
LPP105 has flying lead wires (250 mm / 12" long); all other units have 1/4" tabs.


Input Protection (in addition to reverse polarity):

A

Low-voltage switch off at approximately 9.0 V; High-voltage switch off at approximately 15.0 V.

B

Low-voltage switch off at approximately 18.0 V.

C

Low-voltage switch off at approximately 18.0 V; High-voltage switch off at approximately 34.0.

D

Low-voltage switch off at approximately 36.0 V; High-voltage switch off at approximately 68.0.

E

Low-voltage switch off at approximately 17.0 V; High-voltage switch off at approximately 150V.


Output Protection:

A

Electronic fold back current limit at 6.5 A.

B

Electronic fold back current limit at 10.5 A.

C

Electronic fold back current limit at 21 A.

D

Electronic fold back current limit at 3.5 A.

E

Electronic fold back current limit at 5.3 A.

F

Electronic fold back current limit at approximately 120% of output current, overvoltage crowbar.